Celenit vs Sonablock: Wood Wool Acoustic Panels Compared

If you are specifying mineralised wood wool panels in Italy, Celenit is usually the first name on the list. It is an established Italian manufacturer, it is written into countless capitolati, and most acoustic consultants know the range by heart.

Sonablock is a newer name. The panels are made by Stiga RM in Latvia and supplied across Europe by Wall Panels Pro. The material is the same family: spruce wood wool, mineralised and bound with Portland cement. The question a specifier actually needs answered is narrower than "which brand is better". It is this: at the mounting condition I am going to build, do the two products measure the same, and can I put the evidence in the project file?

This article answers both, using only published documents. Every number below is traceable to a named certificate, test report or EPD.

What the two products have in common

More than the marketing on either side suggests.

Both are wood wool cement board (WWCB) to EN 13168, and both the acoustic ranges are also declared to EN 13964 as suspended ceiling products. Both use Norway spruce. Both are bound with Portland cement, white cement in the finer decorative ranges. Both publish EN 15804+A2 Environmental Product Declarations and both hold PEFC chain of custody. Both carry Euroclass B-s1,d0 in their standard versions and offer an A2-s1,d0 variant.

So this is not a comparison between a proven material and an unknown one. It is a comparison between two manufacturers of the same well understood material, and the differences are in the detail.

The ranges, side by side

Celenit splits its range by wood wool width, which is what drives both the look and the acoustic behaviour. Sonablock does the same thing but names the fibre width directly.

Wood wool width Cement Euroclass
Celenit N 3 mm Grey Portland B-s1, d0
Celenit A / AE 2 mm / 1 mm Grey Portland B-s1, d0
Celenit AB 2 mm White Portland B-s1, d0
Celenit ABE 1 mm White Portland B-s1, d0
Celenit AB/A2, ABE/A2 2 mm / 1 mm White Portland plus mineral powder A2-s1, d0
Sonablock Core Fibre 1.0 1.0 mm White Portland B-s1, d0
Sonablock Core Fibre 1.5 1.5 mm White Portland B-s1, d0
Sonablock Core Fibre 2.0 2.0 mm White Portland B-s1, d0
Sonablock FireSafe 1.0 / 1.5 mm White Portland plus mineral powder A2-s1, d0

The rough equivalences are Sonablock Fibre 1.0 to Celenit ABE, Sonablock Fibre 2.0 to Celenit AB, and Sonablock Fibre 1.5 sitting between the two with no direct Celenit counterpart.

Sound absorption at the same mounting condition

This is where most brand comparisons fall apart, because absorption figures for wood wool are meaningless without the mounting depth and the cavity contents. A 25 mm board fixed flat to concrete and the same board on a 200 mm plenum are different acoustic objects.

So here is the one condition where both manufacturers happen to publish: a 25 mm board with a 200 mm empty air gap behind it, tested in a reverberation room to EN ISO 354 and classified to ISO 11654.

Product Test condition Test body Report or certificate alpha w Class
Celenit AB 25 mm TH 225 mm, empty cavity Istituto Giordano 331332-D 0.65 (H) C
Celenit ABE 25 mm TH 225 mm, empty cavity Istituto Giordano 331334-F 0.65 (H) C
Sonablock Fibre 1.5, 25 mm ODS 200 mm, empty cavity RISE Sweden O100282-1356156 0.65 (H) C
Sonablock Fibre 1.0, 25 mm ODS 200 mm, empty cavity RISE Sweden O100282-1356156 0.60 (H) C

Celenit's TH, total height, is measured from the soffit to the underside of the finish, so TH 225 is a 25 mm board on a 200 mm void. RISE's ODS is the distance from the floor of the chamber to the front face of the sample, so ODS 200 on a 25 mm board is the same geometry. The two are directly comparable.

The result is a tie. Sonablock Fibre 1.5 and Celenit AB and ABE all return a weighted absorption coefficient of 0.65 with an H shape indicator and land in Absorption Class C. Sonablock Fibre 1.0 comes in one step lower at 0.60, still Class C.

Nobody should be surprised by this. It is the same material at the same thickness on the same cavity. Physics does not care about the label. What it does mean is that any claim, from either side, that one brand fundamentally outperforms the other on absorption is not supported by the test data.

The air gap is doing most of the work

Worth dwelling on, because it is the single most common specification error with wood wool.

Celenit publishes an unusually complete set of results for AB at 25 mm, and reading them in order is instructive:

Mounting alpha w Class
Fixed flat, no cavity 0.45 D
30 mm cavity 0.45 D
100 mm cavity 0.60 C
175 mm cavity 0.60 C
200 mm cavity 0.65 C
400 mm cavity 0.60 C
30 mm cavity filled with 80 kg/m³ mineral wool 0.75 C
100 mm cavity, 60 mm of 40 kg/m³ mineral wool 0.90 B
200 mm total construction height: 30 mm of 80 kg/m³ mineral wool plus a 145 mm air gap 0.90 A

The board contributes a fairly narrow band of performance. The cavity, and above all whether you put mineral wool in it, contributes the rest. Going from a bare 25 mm board on the slab to the same board over a filled plenum takes you from Class D to Class A without changing the panel at all.

Celenit's data sheets quote "alpha w up to 0.95" for AB and "up to 1.00" for ABE, and the same data sheets tabulate the mounting condition behind each value (accessed November 2026). Those headline figures require 30 to 60 mm of rock wool at 40 to 80 kg/m³ behind the board, so read every value together with its mounting.

Sonablock's published figure is the empty cavity figure: alpha w 0.65, Class C, bare panel on a 200 mm gap, tested by RISE under report O100282. Add mineral wool behind a Sonablock panel and it will climb the same way Celenit's does, for the same reason. Wall Panels Pro does not currently publish a filled cavity test, so we do not quote a filled cavity number.

If you take one thing from this article: compare products at the mounting condition you are actually going to build, and treat any absorption claim without a stated cavity depth as incomplete.

Fire performance

Both manufacturers offer a standard board at B-s1,d0 and a fire upgraded board at A2-s1,d0, both to EN 13501-1. Low smoke, no flaming droplets, in both cases.

The A2 boards differ from the standard boards in weight and thermal conductivity, so compare those figures as well.

Mass at 25 mm Thermal conductivity
Celenit AB, standard 12.0 kg/m² 0.070 W/mK
Celenit ABE, standard 12.0 kg/m² 0.075 W/mK
Celenit AB/A2, ABE/A2 15.3 kg/m² 0.100 W/mK
Sonablock Core, standard 10.5 kg/m² 0.070 W/mK
Sonablock FireSafe, A2 14.6 kg/m² 0.085 W/mK

Celenit's data sheet describes its A2 boards as made with cement and mineral powder, and the table shows the result: a heavier board with a higher thermal conductivity.

Sonablock's A2 route ends up lighter, 14.6 against 15.3 kg/m², and holds a better lambda, 0.085 against 0.100 W/mK. On a large A2 ceiling, three quarters of a kilo per square metre and a 15 percent difference in conductivity are worth knowing about, particularly where the ceiling is carrying its own weight over a long span or where the buildup is contributing to a thermal calculation.

One caution on the standard boards. Sonablock's 10.5 kg/m² is the mass declared in its verified EPD. Real delivered weight can run above the datasheet figure depending on moisture content at despatch, and anyone planning freight on a full truck should confirm the shipping weight with the supplier rather than working from a technical datasheet.

Thermal performance

Close enough that it rarely decides anything, but for completeness, declared lambda to EN 13168:

Celenit N 0.065, Celenit AB 0.070, Celenit ABE 0.075, Celenit A2 ranges 0.100. Sonablock Core 0.070 as declared in its EPD, with the technical datasheet quoting an average of 0.067 depending on specification, and Sonablock FireSafe 0.085.

Celenit N is the best insulator of the group. It is also the one board here whose current data sheet lists no sound absorption value, so check the data sheet before specifying it for acoustics.

Carbon and EPDs

Both manufacturers publish third party verified EPDs to EN 15804+A2 under the International EPD System, both under PCR 2019:14. Celenit's acoustic ranges sit under EPD-IES-0025754 (version 2, November 2025). Sonablock Core is EPD-IES-0031288 and FireSafe is EPD-IES-0031289.

For Sonablock Core, per square metre of 25 mm board, the EPD declares 6.96 kg CO2 equivalent for the product stage (modules A1 to A3), 0.371 kg CO2 equivalent at end of life (C4), about 9.4 kg CO2 equivalent across modules A1 to C4, and 1.99 kg of biogenic carbon stored in the product.

EN 15804 itself warns that EPDs are only strictly comparable when the declared units, system boundaries and modelling choices align. If carbon is the deciding criterion on your project, read both EPDs rather than any summary of them. Links are at the end.

What you can actually download

This is where a project file gets assembled and a client's technical reviewer starts asking questions, so here is what each maker publishes.

Celenit publishes a data sheet for each of its sound absorption certificates (about 100 on its download page, November 2026), across thicknesses, cavity depths and cavity fills. That library is a real asset, genuinely deeper than anything Sonablock has. Celenit also publishes Declarations of Performance and a CE certificate of constancy of performance on the same page.

The full RISE report O100282 is a downloadable PDF with the one third octave curve, the reverberation room dimensions, temperature and humidity at the time of test, the instrument list and the signatures of the two RISE engineers who ran and checked it. Alongside it sit the CE marking certificate, the Declaration of Performance, the reaction to fire classification report K25/2026, the PEFC chain of custody certificate with its expiry date, the safety data sheet, both EPDs and the technical datasheets for each thickness.

Sonablock will hand you the evidence for the configurations it has tested, in a form you can forward to a client or attach to a submittal without asking anyone's permission.

Looking for a Celenit alternative?

People arrive at this question from a few different directions, and the right answer depends on which one you are in.

You need the same measured absorption, quoted per project. At 25 mm on a 200 mm empty cavity the two products return the same alpha w 0.65 and the same Absorption Class C, from accredited laboratories, to the same standard. Prices should be compared on current quotes for the same thickness, edge and colour, delivered to your site.

You need a clear lead time. Sonablock FireSafe and 35 mm panels are made to order, with a lead time of about 4 weeks (product pages). We confirm the lead time for the rest of the range at quotation.

You need a size, colour or shape that is not in the standard catalogue. Custom RAL and NCS colours, printed faces, custom dimensions and the Design range of shaped and grooved panels are all made to order.

You have been quoted Celenit N and expected acoustic performance. Check the current data sheet for its sound absorption value before you order, because this is the most expensive mistake in the category.

What to check against your project

Four checks before you choose either product.

Procurement requirements. If a tender calls for a specific certification, such as natureplus or Italian CAM Edilizia documentation, ask each manufacturer which of its boards the certificate covers. Celenit's natureplus certificate 1007-1511-134-1 covers its boards including the A2 versions (valid to August 2028 per the certificate), and Celenit states that it provides conformity documentation for the Italian CAM insulation criterion. Confirm the details with the manufacturer.

An unusual mounting condition. Celenit's certificate library covers thicknesses from 15 to 50 mm, cavity depths from zero to 400 mm, and a wide range of mineral wool fills at stated densities. Sonablock currently publishes one acoustic report, at one thickness, at one mounting depth, for two fibre widths. If your ceiling is a 125 mm plenum with 60 mm of 40 kg/m³ rock wool, send us the build-up and we will tell you at quotation which test evidence exists for it.

A filled cavity where you need the number in writing. Sonablock's panels will behave like any other WWCB over a filled plenum, but we do not quote a figure we cannot hand you a report for.

T-grid systems with a specific edge detail. Celenit publishes an edge table by thickness, including rebated edges for T24 and T35 grids. Send us the grid and edge detail and we will confirm at quotation whether Sonablock can match it.

How to specify either product properly

Whichever you choose, a wood wool specification is incomplete without four things, and most of the disappointing rooms we hear about are missing at least one.

State the board thickness. State the cavity depth. State whether the cavity is empty or filled, and if filled, the thickness and density of the mineral wool. Then state the alpha w and absorption class you expect at that exact buildup, with the certificate number that supports it.

If a supplier gives you an absorption figure without a mounting condition attached, ask for the condition before you compare it with anything.

Summary

At 25 mm over a 200 mm empty cavity, Celenit AB, Celenit ABE and Sonablock Fibre 1.5 all measure alpha w 0.65 and Absorption Class C, certified to the same standard by accredited laboratories. That is the comparison that matters and it is a tie.

Around that tie, Sonablock brings a lighter and thermally better A2 board, a complete and downloadable evidence pack, and made to order flexibility on size and colour. Send us the specification and we will confirm at quotation whether Sonablock meets it.

Sources

Sonablock documentation, including the full RISE report, is published at wallpanelspro.com Sonablock documentation.

  • Sound absorption, Sonablock: RISE Research Institutes of Sweden, report O100282-1356156, 3 March 2026, to SS-EN ISO 354 and SS-EN ISO 11654
  • Reaction to fire, Sonablock: classification report K25/2026 to EN 13501-1
  • Sonablock EPD, Core range: EPD-IES-0031288, version date 15 April 2026, valid to 14 April 2031
  • Sonablock EPD, FireSafe range: EPD-IES-0031289, version date 15 April 2026, valid to 14 April 2031
  • Sonablock PEFC chain of custody: BMCERT-PEFC-COC-00175, valid to February 2028
  • Sound absorption, Celenit AB 25 mm at TH 225 empty cavity: Istituto Giordano certificate 331332-D, 11 February 2016
  • Sound absorption, Celenit ABE 25 mm at TH 225 empty cavity: Istituto Giordano certificate 331334-F, 11 February 2016
  • Celenit AB mounting series at 25 mm: Istituto Giordano certificates 331332-A to 331332-E, 333104-A, 324214-B, 324215-B, 324215-D, 324215-E
  • Celenit EPD, AB and ABE ranges: EPD-IES-0025754
  • Celenit technical data and mass, thermal conductivity, edge availability: CELENIT AB and CELENIT ABE schede tecniche ed. 2021/07, and Acoustic Design technical manual

You Might Also Like

Sonablock wood wool acoustic panel, natural, product image

Sonablock 25mm · 1.5mm fibre

€10.40

Sonablock wood wool acoustic panel, natural

Sonablock 25mm · 1.0mm fibre

€11.17

Sonablock wood wool acoustic panel 25 mm, 2.0 mm fibre

Sonablock 25mm · 2.0mm fibre

€9.63

Sonablock wood wool cement board panels

Sonablock 15mm · 1.5mm fibre

€8.09

Sonablock Documentation

Back to blog