Celenit N and Sound Absorption: What the Datasheet Does Not Declare

Celenit N is a good product doing the job it was designed for. It is also the source of the most common and most expensive specification error we see in mineralised wood wool, which is people buying it for acoustics.

This is not a criticism of the board. It is a criticism of how it gets specified, and the fix is simple once you know what to look for.

Start with the document

Open the Celenit N scheda tecnica and look for the sound absorption row.

It is not there (current data sheet, edition 2023/07, checked November 2026).

The datasheet declares thermal conductivity, 0.065 W/mK, the best in the Celenit range. It declares mass, 11.5 kg/m² at 25 mm. It declares compressive stress at 10 percent deformation, water vapour resistance factor, specific heat, chloride content, a Euroclass of B-s1,d0 and a full EN 13168 designation code. It is a thorough datasheet.

There is no alpha w. No NRC. No SAA. No absorption class. No octave band values. No certificate number.

The current Celenit N data sheet lists no sound absorption value. The Celenit AB and ABE data sheets, by contrast, carry a sound absorption entry and a table of tested mountings. If absorption matters for your project, confirm the figure with the manufacturer.

Why not

Because of the wood wool width, and this is where the product actually makes sense.

Celenit N is made with 3 mm wood wool. Celenit AB uses 2 mm and ABE uses 1 mm. Finer wood wool gives a denser, more tortuous surface structure with smaller pores, which is what makes a porous absorber work. Coarse 3 mm wool produces an open, rugged board that is excellent as a substrate, as insulation, as a plaster carrier and as a lost formwork panel. Celenit's N data sheet does not state a sound absorption value.

That is a defensible engineering decision by the manufacturer. The problem happens downstream.

Where it goes wrong

A room needs acoustic treatment. Somebody specifies "Celenit", which everyone in Italy understands to mean wood wool acoustic panels. A quantity surveyor prices the range and orders a board by price rather than by its acoustic data. It arrives, it looks like wood wool, it is fixed to the ceiling.

Then the room is measured, and the reverberation time is not what the acoustic report predicted.

At that point there is no recourse, because the manufacturer never claimed an absorption coefficient. Nobody was misled by Celenit. The specification was simply written against a product that does not declare the performance it was bought for.

What Celenit N is genuinely good at

To be clear, because this is a real product with real uses:

It has the lowest thermal conductivity in the Celenit range at 0.065 W/mK. It is available from 15 to 75 mm thick. It takes plaster and render well, which is its classic role as a bonded substrate. It is structurally robust at 200 kPa compressive stress. It is B-s1,d0.

N has its own uses, and this article is not arguing otherwise. If you want absorption, look for a board with a published test at your mounting condition.

What to specify when the room needs acoustics

You need a board with fine wood wool and, just as importantly, a published test at the mounting condition you are going to build.

Celenit's published absorption data covers its AB and ABE boards. AB 25 mm on a 200 mm empty cavity gives alpha w 0.65, Absorption Class C, under Istituto Giordano certificate 331332-D. ABE 25 mm at the same buildup gives alpha w 0.65, Class C, under certificate 331334-F. Both are documented.

The Sonablock equivalent is the Core range. Sonablock Fibre 1.5 at 25 mm on a 200 mm empty cavity gives alpha w 0.65 with an H shape indicator, Absorption Class C, tested by RISE Research Institutes of Sweden to SS-EN ISO 354 and classified to SS-EN ISO 11654 under report O100282-1356156. Fibre 1.0 at the same buildup gives alpha w 0.60, also Class C.

Which is to say: at the same thickness on the same cavity, Celenit AB, Celenit ABE and Sonablock Fibre 1.5 all measure the same. That is what you would expect from the same material at the same geometry. The absorption coefficient is not what separates them.

Sonablock publishes the full RISE PDF, including the one third octave curve, the chamber dimensions, the temperature and humidity at the time of test and the signatures of the engineers who ran it. Celenit publishes Declarations of Performance, a CE certificate and a data sheet for each absorption certificate (maker's download page, November 2026).

Do not compare absorption figures without the mounting condition

The other half of the problem is that even correctly specified wood wool gets compared badly, because absorption figures for this material are close to meaningless on their own.

Here is Celenit AB at 25 mm, the same board throughout, at different buildups:

Mounting alpha w Class
Fixed flat to the slab 0.45 D
30 mm cavity 0.45 D
100 mm cavity 0.60 C
200 mm cavity 0.65 C
30 mm cavity with 80 kg/m³ mineral wool 0.75 C
200 mm total construction height: 30 mm of 80 kg/m³ mineral wool plus a 145 mm air gap 0.90 A

Class D to Class A, from the same panel. The cavity is doing most of the work.

Celenit's data sheets quote "alpha w up to 0.95" for AB, and the same data sheets tabulate the mounting condition behind each value (accessed November 2026). That headline figure requires a filled cavity, so read every value together with its mounting.

The same caution applies in our direction. Sonablock's published alpha w 0.65 is an empty cavity figure. Put mineral wool behind a Sonablock panel and it will climb the same way, for the same physical reason, but we do not publish a filled cavity number because we do not yet have a filled cavity test to hand you.

A four line specification that prevents all of this

Whatever brand ends up in the room, write these four things down:

  1. Board thickness in mm, and the wood wool width
  2. Cavity depth in mm
  3. Cavity contents, either empty or the thickness and density of the mineral wool
  4. The required alpha w and absorption class at that exact buildup, with the certificate number that supports it

If a datasheet cannot give you point four for the product being offered, that product has not been tested for what you are buying it for. That is the whole of the Celenit N story, and it applies equally to anyone else's board.

Summary

The current Celenit N data sheet (edition 2023/07) lists no sound absorption value. It is a capable insulation and plaster carrier board.

If the room needs acoustics, specify a fine wood wool board with a test report that matches your buildup. Sonablock Core has one: alpha w 0.65 and Absorption Class C at 25 mm on a 200 mm empty cavity, with the test report available to download. Send us the specification and we will confirm at quotation whether Sonablock meets it.

Sources

  • Celenit N technical data: CELENIT N data sheet, edition 2023/07, and Declaration of Performance 01-CELN-02 (maker's download page, accessed November 2026)
  • Celenit AB 25 mm, TH 225 empty cavity: Istituto Giordano certificate 331332-D, 11 February 2016
  • Celenit ABE 25 mm, TH 225 empty cavity: Istituto Giordano certificate 331334-F, 11 February 2016
  • Celenit AB mounting series at 25 mm: Istituto Giordano certificates 331332-A, 331332-B, 331332-C, 331332-D, 333104-A, 324214-B, 324215-E
  • Sonablock sound absorption: RISE Research Institutes of Sweden, report O100282-1356156, 3 March 2026, to SS-EN ISO 354 and SS-EN ISO 11654. Published in full at wallpanelspro.com Sonablock documentation

You Might Also Like

Sonablock wood wool acoustic panel, natural, product image

Sonablock 25mm · 1.5mm fibre

€10.40

Sonablock wood wool acoustic panel, natural

Sonablock 25mm · 1.0mm fibre

€11.17

Sonablock wood wool acoustic panel 25 mm, 2.0 mm fibre

Sonablock 25mm · 2.0mm fibre

€9.63

Celenit vs Sonablock Compared

Sonablock Documentation

Back to blog